Pc1832 programming manual

Doing so may cause problems in the function of your alarm system.

Forever nerd and SaaS entrepreneur. Intrigued by software engineering, software as a business and aviation. I purchased the IT board and then decided I wanted to expand it a bit further to include more zones. I quickly realized I could use the IT board and some time to systematically determine the installer code but the time spent on that would be spent only because I had some concerns regarding reprogramming it. I decided to reprogram it myself and here are my notes for anyone attempting to program or even reprogram their own DSC alarm. The process is incredibly straight forward with only a few caveats.

Pc1832 programming manual

.

You need to map out all of your zones.

.

Table Of Contents. Table of Contents. Quick Links. This manual contains information on limitations regarding product use and function and information on the limitations as to liability. The entire manual should be carefully read.

Pc1832 programming manual

.

Trabajos en walmart

We will make the Front Door sensor delayed in zone 01, the Smoke Alarm will be standard 24 hour monitoring in zone 02, the Bedroom Window Sensor we will have Instant arming and disarming in zone This code is what you use to arm and disarm the system with. Okay, now it is reset and ready for programming. Example: 1, 2, 3, 4, 5 would be zones 9, 10, 11, 12, 13 If you are using 17 or more, but less than 24 zones, use programming section add 16 to each numbered zone to get that zone. You need to map out all of your zones. You must keep your wireless zones somewhere in the first 32 zones. Press Since you did not use resistors, we need to turn off option 6 and we need to make sure option 1 is on. This code is only used to get into programming and nothing else. Enter section and enter 1 2 3 4, system will beep 3 times Now hit. You will go over the zone number in the programming section and turn on toggle option 8 on. Step 2 Adding Zone Definitions Program Section We will begin adding our Zone Definitions and will use the above chart for reference and we will go straight down the list which begins with Zone Number Then the keypad will ask for a two-digit section.

.

Here is how I programmed it and the order I went through: Enroll the keypads Switch to normally-closed loops non-resistive circuits Program the zones Cancel the telephone system as it is monitored via the Internet Set the partitioning for expanded zones Check the devices Reset the master code Reset the installer code victory Items of Note I programmed my system in a single partition partition 1 My alarm is monitored via the Internet and not via the telephone system s built into the DSC Enroll the Keypads I have four keypads plus the IT so my keypad bus is busy. The panel will ask to confirm the ESN number. Taking the Sample Alarm Kit above and using the common Zone Definitions, here is what we want to do with the system. Version 4. The DSC factory resets with zones 9-X in partition 0 so they do not appear in partition 1 automatically. After you have enrolled and confirmed each device hit to exit. The letters of the alphabet are divided up among the number keys on the keypad as described:. You will want to enter programming by entering:. Enter again. Enter section and enter 05 05, system will beep 3 times. A quick triple beep means the system accepted you entry and is now ready for the next entry.

1 thoughts on “Pc1832 programming manual

Leave a Reply

Your email address will not be published. Required fields are marked *